Laboratory Automatic Chemistry Analyzer machine System URIT-8021A

The Automatic chemistry analyzer machine URIT-8021A provides cost-effective testing for small and mid-sized laboratories. chemistry analyzers meet the highest quality standards and have proven to be the best choice in today’s modern routin

12 La gente viendo este producto ahora!
  • Retiro en Casa Matriz

Haz tu pedido y retira directamente

1-2 Días

Gratuito

  • Envío a Domicilio
Antes de comprar verifica el día en que despachamos a tu comuna

2-3 Días

Costo Variable

  • Certificado de Calidad
  • Empaque y Traslado Seguro

Prefiera Tarjetas Débito o Crédito:


Automatic-Chemistry-Analyzer-machine-URIT-8021A



Durable ceramic syringes Chemistry Analyzer machine URIT-8021A Features 


24 hour non-stop cooling system to ensure reagent at 2-8℃



Durable ceramic syringes to ensure accuracy & precision


High accurate optical system


Collision protection in both vertical and horizontal directions, stop & alarm automatically


once touching barrier, not affect former tests


Automatic eligible cuvettes detection & selection


Select best test point by reaction curve, create new factor automatically


Support LIS interface 



Automatic-Chemistry-Analyzer-machine-URIT-8021A-1



Automatic eligible cuvettes detection Chemistry Analyzer machine URIT-8021A Specifications


Assay methods: End Point, Kinetic, Fix time etc.


Principle: Photoelectric colorimetry


Light Source: Halogen lamp 12V/20W


Photometry range: 0~3.2Abs


Resolution: 0.0001Abs


Wavelength: 340nm405nm450nm492nm510nm546nm578nm630nm700nm800nm


Throughput: 200 tests/hour


Reagent tray: 60 reagent positions (include1detergent position,1 dilution position)


Sample tray: 71 sample positions, including detergent, standard, QC, STAT positions


Reaction tray: 120 reaction cuvettes


Sample volume: 2~100ul, with 0.1ul increment


Reagent volume: R1:10~500uL, R2: 10~500uL,with 0.5uL increment


Minimum reaction volume: 180uL


Maximum reaction time: 10 minutes


Water Consumption: Less than 5L/hour under working status


Clean unit: 8-step auto-washing system with detergent


Calibration: Calibration reset, select best test point by reaction curve, no need second calibration


Line/non-line;multi-standards assay


Control rules: Westgard multi-rule, Cumulative sum check, Twin plot


3 level controls for each ifem, analyxing and printing QC analysis diagram


Temperature control: incubator 37±0.1℃


Power supply: AC 230(1±10%)V, 50/60Hz, 500VA


Ambient: Operating temperature: 10~30℃


Relative humidity: ≤85%


Atmospheric pressure: 86~106kPa 


 


Automatic-Chemistry-Analyzer-machine-URIT-8021A-2


 



High performance mixer design 



Absence of cross contamination


Optimal homogenization in minimum time


Mixing immediately after dispensing of sample and the second reagent


 


Automatic-Chemistry-Analyzer-machine-URIT-8021A-3


 



Stable Optical System




High accurate, close, static state optical system


Spot photometry with high speed digital transmission system


Durable cuvettes


8-step auto-washing system with detergent and deion-water to ensure


cuvettes clean and decrease cross contamination


120 reaction cuvettes located in a constant temperature incubator


Low consumption, open reagent design



 


Automatic-Chemistry-Analyzer-machine-URIT-8021A-4


 


 


 


 